RS-MGR1
RS-MGR1 System Requirements
- Operating system (X86/X68 versions)
Windows Vista® SP2 or later
Windows® 7 SP1 or later
Windows® 8 (Except Windows RT)
Windows Server® 2003 SP2 or later
Windows Server® 2008 SP2 or later
Windows Server® 2008 R2 SP1 or later
Windows Server® 2012 - Memory: 2GB or higher
- Hard disk space: 500GB of minimum disk space 20MB × Number of repeaters × Days for saving logs + 100GB recommended
- Display resolution: 1280×1024 Pixel or more recommended
- LAN: 100Mbps or faster (Fixed IP address required)
- Other: USB 2.0 port, sound card and speaker UC-FR5000 MCU revision 4.00 or later
Remote System Manager Software for IDAS™ NXDN™ Multi-Site Trunking System
![]()
The RS-MGR1 system manager software allows you to obtain air time information, network connectivity/statistics and hardware status of the IDAS multi-site trunking repeater sites using syslog messages. The RS-MGR1 stores received syslog messages and reports and analyzes them to assist in system administration and troubleshooting.
Main Features
- Repeater properties show condition summary, system information, interface (traffic statistics), repeater condition details (TX/RX PLL unlock, power supply voltage, internal temperature and fan status) and ping status of each repeater
- Registration log, communication log, traffic log and search log can be filtered by date, user ID, call type and site code*
*Filter items differ from log types - E-mail alert notification can be sent to the administrator, if an alarm or disconnect occurs or clears
- The "Mesh ping status" shows the connectivity by sending ping commands in all combinations of repeater sites
- The "Version list" shows the repeaters firmware revision list
- The "Map window" shows repeater site icons laid out on a image file such as a map or network diagram
- USB flash drive containing the software and for the hardware key protection
- SR-VPN1 VPN router can be monitored on the RS-MGR1 by syslog
Network Diagram

Repeater Properties

Traffic Log

Mesh Ping Status

Version List

System Settings

General
| Frequency range | Tx | 156.025–157.425 MHz |
|---|---|---|
| Rx | 156.050–163.275 MHz | |
| Rx (CH70) | 156.525 MHz | |
| RX (AIS) | 162.025 MHz | |
| Usable channel groups | INT, USA, CAN, WX channels | |
| Type of emission | 16K0G3E (FM), 16K0G2B (DSC), 16K0GXW (GMSK) | |
| Current drain (at 7.2 V DC) |
TX (6 W/1 W output) | 1500 mA/700 mA (approx.) |
| RX (Inter SP/Exter SP Max. audio) | 700 mA/350 mA (approx.) | |
| Operating temperature range | –20°C to +60°C; –4˚F to +140˚F | |
| Antenna impedance | 50 Ω | |
| Dimensions (W×H×D) (Projections not included) |
60.9 × 145.8 × 43.8 mm; 2.4 × 5.7 × 1.7 in |
|
| Weight (approximately) | 357 g ; 12.6 oz (With BP-306, antenna, MB-133) |
|
Transmitter
| Output power (Hi/Low) | 6 W/1 W | |
|---|---|---|
| Max. frequency deviation | ±5 kHz | |
| Frequency stability | ±10 ppm | |
| Spurious emissions | –68 dBc typical | |
Receiver
| Sensitivity (at 12 dB SINAD) DSC receiver (at 1% BER) AIS receiver (at 20% PER) |
0.25 μV typical –3 dBμ emf typical –107 dBm |
|
|---|---|---|
| Squelch sensitivity (Threshold) | 0.25 μV typical | |
| Adjacent channel selectivity DSC receiver (at 1% BER) AIS receiver (at 20% PER) |
70 dB typical 73 dBμ emf 50 dB typical |
|
| Spurious response DSC receiver (at 1% BER) AIS receiver (at 20% PER) |
70 dB typical 73 dBμ emf 50 dB typical |
|
| Intermodulation DSC receiver (at 1% BER) AIS receiver (at 20% PER) |
70 dB typical 68 dBμ emf 50 dB typical |
|
| Hum and noise | 40 dB | |
| Audio output power (at 10% distortion) |
Internal SP | 1500 mW typical (8 Ω load) |
| External SP | 350 mW typical (8 Ω load) | |
Measurements made in accordance with TIA/EIA-603. All stated specifications are subject to change without notice or obligation.
Applicable U.S. Military Specifications & IP Rating
| Standard | MIL-810 G | |
|---|---|---|
| Method | Procedure | |
| Low Pressure | 500.5 | I, II |
| High Temperature | 501.5 | I, II |
| Low Temperature | 502.5 | I, II |
| Temperature Shock | 503.5 | I-C |
| Solar Radiation | 505.5 | I |
| Rain Blowing/Drip | 506.5 | I, III |
| Humidity | 507.5 | II |
| Salt Fog | 509.5 | – |
| Dust Blowing | 510.5 | I |
| Immersion | 512.5 | I |
| Vibration | 514.6 | I |
| Shock | 516.6 | I, IV |
Also meets equivalent MIL-STD-810-C, -D, -E and -F.
| Ingress Protection Standards | |
|---|---|
| Water | IPX7 (Waterproof protection) |
All stated specifications are subject to change without notice or obligation.
Supplied Accessories
- BP-306 battery pack
- BC-251 battery charger
- AC adapter*
- CP-26 cigarette lighter cable
- MB-133 belt clip
- Antenna
- Hand strap
* May differ depending on version




Reviews